Skip to content

Streaming Current Detectors (SCD)

Key Benefits Include: 

vector

Online monitoring of the colloidal charge.

automated

4-20mA output of the process variable for connection to an automated control loop for flocculant addition.

smoke detector

Proven sensor design and reliability of operation. Keypad navigation and ease of setup/calibration.

time management

Using the LDT 16, online results can easily be verified, as well as using it for charge surveys at various points in the process to evaluate chemical dosing efficiency.

f
SCD 16mp

This unit is a process monitoring device that is located in a sample pot in a side stream of the process. The typical location would be a few minutes downstream of a chemical addition point in the process, to enable the operator to monitor changes in colloidal charge in conjunction with changes in chemical addition rates or other process related variables.

SCD 16mp Product Flier and spec sheet 

SCD 16mp Operating Manual

SCD 16mp calibration guide

SAM SET SS

SCD 16Plus

This SCD has a built-in PI controller and the control output can be set from the menu to be 4-20mA or a pulsed output potential free contact with a range of 20 to 255 pulse/minute relating to the control output range of 0 – 100%.

  • The charge signal is available as a 4-20 mA output.
  • This output type can be used with any standard field instrumentation, for recording and control purposes

SCD 16Plus Product Flier and spec sheet 

SCD 16Plus Operating Manual

SCD 16Plus calibration guide

SCD 16plus
LDT16 Image
LTD 16mp (Laboratory Demand Titrator)

The SCD 16mp process instrument can give valuable results in the lab when monitoring of multiple sample points in the plant with individual units is not an economic option. The unit is completely portable, contains all the necessary equipment to conduct test work and can be rapidly set up anywhere. Laboratory work with this instrument is made easy with the instrument itself being hinged in the carry case and its ability to readily accept the sample. The sample can be kept mixed with the use of the Lechintech (PTY) LTD Magnetic Stirrer, which comes standard fitted into the carry case. The instrument and all of its accessories are housed in a tough aluminium carry case. 

Included with LTD 16mp: 

– Sturdy aluminium carry case.
– Magnetic stirrer and bead.
– 2 x 1-litre beakers.
– 2 x 100 ml beakers.
– 1 x 10 ml pipette.
– 1 x 1 ml pipette.
– 1 bottle cationic standard.
– 1 bottle anionic solution
– 2 x 5ml syringes.

LDT 16mp Product Flier and spec sheet 

LDT 16 Operating manual

Entrained Air Monitor online unit

The Lechintech (PTY (Ltd) online EAM is a batch process unit that has its own local processor and setup parameters for a single sample system.

The online unit can monitor entrained air values up to 10%, with applications on the paper machine and in the pulp mill. It can also be adapted to monitor more than one sample on a sequential basis, with the use of an automated valve manifold controlled from the DCS. The unit has a 4-20mA process signal output and digital alarm and hold output for remote monitoring and control.

It can also be adapted to monitor more than one sample on a sequential basis, with the use of an automated valve manifold controlled from the DCS. The unit has a 4-20mA process signal output and digital alarm and hold output for remote monitoring and control.

The unit has a 4-20mA process signal output and digital alarm and hold output for remote monitoring and control.

EAM online installation and Operating Manual

Entrained Air Monitor online unit

Signal Interface (SRC)

Key Benefits Include: 

split

For use when two different chemicals are being dosed in a specific ratio.

switch

Gives the flexibility for the use of a duty and standby pump, which will automatically allow for extended control in extraordinary conditions.

Split Range Converter 1
Split Range Converter 2
Split Range Converter (SRC)

The Lechintech (PTY) LTD Split Range Converter modifies a single 4-20mA signal and converts it into two outputs. The card can be configured to give two identical 4-20mA outputs, or to give a split range output, generally a 50-50 split as depicted in the graph below. The card can be ordered in 110 or 220 VAC and can be configured to give up to a 30-70% split

SRC Product Flier and spec sheet 

Signal Interface (I to F)

Key Benefits Include: 

link

Allows for the connection of a 4-20mA control output to a dosing pump with a pulsed speed input.

parallel

For use when two dosing pumps are utilised in parallel.

ratio

Gives the flexibility for the use of two pumps in a fixed ratio dosing two different chemicals.

I to F Image
Current to Frequency Converter

The Lechintech PTY (Ltd) I to F (current to frequency converter) takes a 4-20mA input and converts it to a pulse output. The output is two potential free contacts rated at 1 amp in alternating action. The duty cycle is 50% and is DIP switch selectable from 1 pulse per minute to 255 pulses per minute. The power supply is 220 VAC with 110 VAC as an option.

I to F Product Flier and spec sheet 

Prefabricated Units

03-ID6A2321

Mobile Dose Unit

04-ID6A2322

Control and Alarm Panels

06-ID6A2325

Signal Termination Box

12-ID6A2340

Fibreglass Pump Bracket with Euro Plug Socket

Chlorine Products

07-ID6A2326

Auxiliary Block valves

08-ID6A2329

Flex Connectors
( 1.2m and 2m)

13-ID6A2344

Fibreglass Yellow Safety Box

10-ID6A2332-001

Heated Liquid Trap

16-ID6A2347

Chlorine Spanners

LECDRROLL_3b

Chlorine 1 Tonne Drum Rollers

SERVICES

Lechintech PTY (Ltd) offer both on site and work shop service for all of the equipment that we supply. We issue certificates of calibration and service for the equipment we test in our workshop, and will supply a call report on all site work conducted. We are happy to quote for your specific requirements for either the on site or workshop options. We charge for distance traveled and time on site, or quote free of charge for repairs in our workshop providing the equipment is delivered free to the workshop. If the quote is not accepted the components will be crated and shipped back to site at your cost..

On-Site

The onsite servicing of the Lechintech PTY (Ltd) equipment will be limited to basic servicing, parts replacement and standard calibration. Any electronic repairs and testing will be conducted in our laboratories at our discretion.

Workshop

The workshop staff can undertake a full refurbishment of all equipment supplied by Lechintech PTY (Ltd) if it is serviceable. Replacement of components are at the sole discretion of the Lechintech PTY (Ltd) staff, once a full-service investigation has been done.

Our Distributors

The following representatives can assist world wide:

  • Process Control Services – Australia
  • True Bio Science – Malaysia
Capture
J20355_CGSO_New Meber Web Icon (003)